{"id":21074,"date":"2024-07-30T11:26:14","date_gmt":"2024-07-30T03:26:14","guid":{"rendered":"https:\/\/www.rocker.com.tw\/?post_type=application&#038;p=21074"},"modified":"2026-04-21T15:05:56","modified_gmt":"2026-04-21T07:05:56","slug":"peristaltic-pump","status":"publish","type":"application","link":"https:\/\/www.rocker.com.tw\/en\/application\/peristaltic-pump\/","title":{"rendered":"Peristaltic Pump"},"content":{"rendered":"<h1><span style=\"font-size: 22px;\">Peristaltic Pump, The Ultimate Tool for Liquid Distribution in Laboratories!<\/span><\/h1>\n<p>&nbsp;<\/p>\n<div style=\"background-color: #e9eef0; padding: 30px 20px;\"><span style=\"font-size: 20px;\"><strong>Content<\/strong><\/span><br \/>\n<a href=\"#P1\">What is a Peristaltic Pump?<\/a><br \/>\n<a href=\"#P2\">Peristaltic Pump Operation<\/a><br \/>\n<a href=\"#P3\">Advantages and Features of Peristaltic Pumps<\/a><br \/>\n<a href=\"#P4\">Factors Affecting Peristaltic Pump Performance<\/a><br \/>\n<a href=\"#P5\">How to Maintain a Peristaltic Pump?<\/a><br \/>\n<a href=\"#P6\">How to Select the Appropriate Peristaltic Pump Tubing??<\/a><br \/>\n<a href=\"#P7\">Laboratory Peristaltic Pumps Applications<\/a><\/p>\n<p><a href=\"#P8\">Frequently Asked Questions (FAQ)<\/a><\/p>\n<\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h2 style=\"text-align: justify;\"><span style=\"font-size: 20pt;\"><span style=\"font-family: 'Myriad Pro Light',sans-serif;\"><strong><span style=\"font-family: '\u5fae\u8edf\u6b63\u9ed1\u9ad4',sans-serif;\"><a id=\"P1\"><\/a>What is a Peristaltic Pump?<\/span><\/strong><\/span><\/span><\/h2>\n<p>&nbsp;<\/p>\n<p style=\"text-align: justify;\">A lab peristaltic pump, also known as a roller pump, is a type of positive displacement pump. It is commonly used in laboratories for precise measurement and transfer of liquids.<\/p>\n<p style=\"text-align: justify;\">The main advantage of a peristaltic pump is that only the peristaltic tubing comes into contact with the liquid, eliminating the risk of contamination. This makes it particularly important in sterile, precise control and cross-contamination prevention applications, such as medical, pharmaceutical, cell biology, and microbiology laboratories.<\/p>\n<p>&nbsp;<\/p>\n<div style=\"background-color: #e9eef0; padding: 10px 20px;\"><strong>Read more:<\/strong>\u00a0<a title=\"Life Sciences Instruments and Equipment - Rocker\" href=\"https:\/\/www.rocker.com.tw\/en\/product-category\/life-sciences\/\" target=\"_blank\" rel=\"noopener\">Life Sciences Instruments and Equipment &#8211; Rocker<\/a><\/div>\n<p>&nbsp;<\/p>\n<hr \/>\n<p>&nbsp;<\/p>\n<h2 style=\"text-align: justify;\"><span style=\"font-size: 20pt;\"><span style=\"font-family: 'Myriad Pro Light',sans-serif;\"><strong><span style=\"font-family: '\u5fae\u8edf\u6b63\u9ed1\u9ad4',sans-serif;\"><a id=\"P2\"><\/a>Peristaltic Pump Operation<\/span><\/strong><\/span><\/span><\/h2>\n<p>&nbsp;<\/p>\n<p style=\"text-align: justify;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: 'Myriad Pro Light',sans-serif;\"><span style=\"font-family: '\u5fae\u8edf\u6b63\u9ed1\u9ad4',sans-serif;\">The operating principle involves a motor driving rollers that compress the peristaltic pump tubing. This creates a vacuum, drawing in the liquid. <\/span><\/span><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: 'Myriad Pro Light',sans-serif;\"><span style=\"font-family: '\u5fae\u8edf\u6b63\u9ed1\u9ad4',sans-serif;\">As the rollers rotate, the liquid is pushed out, effectively transporting the fluid. The tight fit between the tubing and rollers ensures that there is no backflow or siphoning when the pump stops.<\/span><\/span><\/span><\/p>\n<p>&nbsp;<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.rocker.com.tw\/wp-content\/uploads\/2024\/07\/Pump_Slow.gif\" alt=\"Operating Principle of a Peristaltic Pump\" width=\"45%\" \/><\/p>\n<p>&nbsp;<\/p>\n<hr \/>\n<h2>\u00a0<\/h2>\n<h2 style=\"text-align: justify;\"><span style=\"font-size: 20pt;\"><span style=\"font-family: 'Myriad Pro Light',sans-serif;\"><strong><span style=\"font-family: '\u5fae\u8edf\u6b63\u9ed1\u9ad4',sans-serif;\"><a id=\"P3\"><\/a>Advantages and Features of Peristaltic Pumps <\/span><\/strong><\/span><\/span><\/h2>\n<p>&nbsp;<\/p>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li><strong>Accurate Dosing:<\/strong> Precisely control the flow rate, ensuring consistent liquid delivery, suitable for high-accuracy scientific experiments and biotech processes.<\/li>\n<li><strong>Quantitative Dosing:<\/strong> The pump parameters can be set to accurately measure the volume of liquid transported, achieving precise quantitative distribution.<\/li>\n<li><strong>Flow Regulation:<\/strong> The flow rate of the liquid can be adjusted to meet different experimental conditions.<\/li>\n<li><strong>Dry Running Capability:<\/strong> The pump can operate without liquid, making it durable in various experimental environments.<\/li>\n<li><strong>Self-Priming:<\/strong> Peristaltic pumps can automatically draw in liquid without additional priming devices.<\/li>\n<li><strong>Interchangeable Pump Heads:<\/strong> Users can replace the pump head as needed to accommodate different types and sizes of tubing, enhancing flexibility.<\/li>\n<li><strong>Wide Range of Fluid Compatibility:<\/strong>\u00a0A Peristaltic pump can handle various types of fluids, including corrosive, abrasive, viscous, and shear-sensitive liquids.<\/li>\n<li><strong>No Contamination Risk:\u00a0<\/strong>Only the tubing contacts the liquid, reducing the risk of contamination.<\/li>\n<li><strong>Easy Maintenance and Low Cost:<\/strong> The tubing is easy to replace and clean, and the simple design results in lower maintenance costs.<\/li>\n<li><strong>Reversible Operation:<\/strong> The pump head can rotate in both directions, allowing bidirectional fluid flow.<\/li>\n<li><strong>No Slip: <\/strong>Ensures precise and stable fluid transfer without slippage.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h3 style=\"text-align: center;\"><span style=\"font-size: 16pt;\"><span style=\"font-family: 'Myriad Pro Light',sans-serif;\"><strong><span style=\"font-family: '\u5fae\u8edf\u6b63\u9ed1\u9ad4',sans-serif;\">All Advantages in One &#8211; <br \/>\n<\/span><\/strong><\/span><\/span><span style=\"font-size: 16pt;\"><span style=\"font-family: 'Myriad Pro Light',sans-serif;\"><strong><span style=\"font-family: '\u5fae\u8edf\u6b63\u9ed1\u9ad4',sans-serif;\">Buller 600 ( Buller 600 &#8211; DSP ) Dispensing Peristaltic Pump!<\/span><\/strong><\/span><\/span><\/h3>\n<blockquote>\n<table class=\"no-border\">\n<tbody>\n<tr>\n<td style=\"vertical-align: middle;\" rowspan=\"2\" width=\"60%\">\n<p><strong><a href=\"https:\/\/www.rocker.com.tw\/en\/product\/food-analysis\/peristaltic_pump-dsp\/buller-600-dsp-dispensing-peristaltic-pump\/\" target=\"_blank\" rel=\"noopener\">Rocker Buller 600 (Buller 600 &#8211; DSP)<\/a><\/strong><\/p>\n<p><strong>\uff0d\u3000Built-in microbiological dispensing mode<\/strong><br \/>\n<strong>\uff0d\u3000DSP equipped with a handheld dispenser, ergonomically designed for easy grip<\/strong><br \/>\n<strong>\uff0d\u3000Features a reverse suction function to reduce dispensing errors<\/strong><\/p>\n<p>&nbsp;<\/p>\n<p>Buller 600 (Buller 600 &#8211; DSP) is designed for microbiological experiments and has passed multiple international certifications, making it an effective assistant for liquid dispensing in microbiological and biomedical laboratories!<\/p>\n<\/td>\n<td width=\"40%\"><img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/www.rocker.com.tw\/wp-content\/uploads\/2024\/06\/Buller-600_DSP-scaled.jpg\" alt=\"Buller Dispensing Peristaltic Pump\" width=\"2560\" height=\"1707\" \/><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">\n<p><strong><a href=\"https:\/\/www.rocker.com.tw\/en\/product\/laboratory-pump-en\/dispensing-peristaltic-pump-p-en\/buller-600-dispensing-peristaltic-pump\/\">Buller 600 Peristaltic Pump<\/a><\/strong><\/p>\n<p><strong><a href=\"https:\/\/www.rocker.com.tw\/en\/product\/food-analysis\/peristaltic_pump-dsp\/buller-600-dsp-dispensing-peristaltic-pump\/\">Buller 600 &#8211; DSP Peristaltic Pump<\/a><\/strong><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/blockquote>\n<figure id=\"attachment_29055\" aria-describedby=\"caption-attachment-29055\" style=\"width: 900px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.rocker.com.tw\/en\/contact\/\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"wp-image-29055 size-full\" src=\"https:\/\/www.rocker.com.tw\/wp-content\/uploads\/2023\/04\/rocker-scientific-global-dealer-network-quick-quote-1.webp-1.webp\" alt=\"Rocker Global Dealer Network banner offering dedicated support from local experts in USA, India, China, Indonesia, Malaysia, and worldwide for quick quotes.\" width=\"900\" height=\"120\" srcset=\"https:\/\/www.rocker.com.tw\/wp-content\/uploads\/2023\/04\/rocker-scientific-global-dealer-network-quick-quote-1.webp-1.webp 900w, https:\/\/www.rocker.com.tw\/wp-content\/uploads\/2023\/04\/rocker-scientific-global-dealer-network-quick-quote-1.webp-1-768x102.webp 768w, https:\/\/www.rocker.com.tw\/wp-content\/uploads\/2023\/04\/rocker-scientific-global-dealer-network-quick-quote-1.webp-1-600x80.webp 600w\" sizes=\"(max-width: 900px) 100vw, 900px\" \/><\/a><figcaption id=\"caption-attachment-29055\" class=\"wp-caption-text\">Global expert support across USA, Asia, and worldwide. \u25b2Click to get a quick quote from your local Rocker dealer.<\/figcaption><\/figure>\n<p>&nbsp;<\/p>\n<hr \/>\n<p>&nbsp;<\/p>\n<h2 style=\"text-align: justify;\"><a id=\"P4\"><\/a>Factors Affecting Pump Performance<\/h2>\n<p>&nbsp;<\/p>\n<p style=\"text-align: justify;\">The performance of a peristaltic pump in liquid distribution (flow rate) can be affected by the following factors:<\/p>\n<p>&nbsp;<\/p>\n<ul>\n<li><strong>Speed:<\/strong> Higher speed increases flow rate.<\/li>\n<li><strong>Viscosity:<\/strong> Lower viscosity results in higher flow rate.<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"https:\/\/www.rocker.com.tw\/wp-content\/uploads\/2024\/07\/17-6-\u5b98\u7db2\u61c9\u7528\u5716\u793a-\u8815\u52d5\u5e6b\u6d66_\u6d41\u91cf\u8207\u7ba1\u5167\u5f91\u5927\u5c0f\u6210\u6b63\u6bd4\u5716-En-scaled.jpg\" alt=\"Peristaltic pump viscosity\" width=\"75%\" \/><\/p>\n<p>&nbsp;<\/p>\n<ul>\n<li><strong>Number of Rollers:<\/strong> Fewer rollers increase flow rate but more rollers reduce pulsation and ensure stable operation.<\/li>\n<li><strong>Tubing Inner Diameter:<\/strong> Larger inner diameter increases flow rate but decreases dosing accuracy.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<hr \/>\n<p>&nbsp;<\/p>\n<h2 style=\"text-align: justify;\"><a id=\"P5\"><\/a>How to Maintain a Peristaltic Pump?<\/h2>\n<p>&nbsp;<\/p>\n<p><span style=\"font-size: 12pt;\"><span style=\"font-family: 'Myriad Pro Light',sans-serif;\"><span style=\"font-family: '\u5fae\u8edf\u6b63\u9ed1\u9ad4',sans-serif;\">Peristaltic pumps are simple in structure, with no valves or seals, and the only maintenance part is the tubing. <\/span><\/span><\/span><\/p>\n<p><span style=\"font-size: 12pt;\"><span style=\"font-family: 'Myriad Pro Light',sans-serif;\"><span style=\"font-family: '\u5fae\u8edf\u6b63\u9ed1\u9ad4',sans-serif;\">After use, the tubing can be easily removed and cleaned by opening the pump head, saving time and maintenance costs. <\/span><\/span><\/span><\/p>\n<p><span style=\"font-size: 12pt;\"><span style=\"font-family: 'Myriad Pro Light',sans-serif;\"><span style=\"font-family: '\u5fae\u8edf\u6b63\u9ed1\u9ad4',sans-serif;\">Regularly replace the tubing based on the manufacturer&#8217;s recommendations, as continuous compression and friction can cause aging, deformation, and loss of elasticity.<\/span><\/span><\/span><\/p>\n<p>&nbsp;<\/p>\n<hr \/>\n<p>&nbsp;<\/p>\n<h2 style=\"text-align: justify;\"><a id=\"P6\"><\/a>How to Select the Appropriate Peristaltic Pump Tubing?<\/h2>\n<p>&nbsp;<\/p>\n<p>The choice of tubing material is crucial as the fluid comes into direct contact with it.<\/p>\n<p>Common materials include PVC, silicone rubber, fluoroelastomer (e.g., FKM, FFKM), thermoplastic elastomer (TPE, e.g., PharMed), and thermoplastic vulcanizates (TPV).<\/p>\n<p>&nbsp;<\/p>\n<h3 style=\"text-align: justify;\"><span style=\"font-size: 16pt;\"><span style=\"font-family: 'Myriad Pro Light',sans-serif;\"><strong><span style=\"font-family: '\u5fae\u8edf\u6b63\u9ed1\u9ad4',sans-serif;\">Factors to Consider When Choosing Peristaltic Pump Tubing Material:<\/span><\/strong><\/span><\/span><\/h3>\n<p>&nbsp;<\/p>\n<ul>\n<li><strong>Chemical Compatibility:<\/strong> Select tubing based on the chemical properties of the fluid.<\/li>\n<li><strong>Tubing Size:<\/strong> Select the appropriate peristaltic pump tubing diameter based on the desired flow rate. Flow rate is directly proportional to the inner diameter of the tubing but inversely proportional to dispensing accuracy. For more viscous liquids, it is recommended to use tubing with a larger inner diameter. Additionally, the outer diameter (thickness) of the tubing affects the fit between the tubing and the rollers. If the outer diameter is too thin, resulting in a poor fit, the peristaltic pump will not operate effectively; if it is too thick, it will cause excessive wear on the tubing and shorten the pump&#8217;s lifespan. Choose the suitable peristaltic pump tubing diameter according to the recommendations of the peristaltic pump manufacturer.<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"https:\/\/www.rocker.com.tw\/wp-content\/uploads\/2024\/07\/17-4-\u5b98\u7db2\u61c9\u7528\u5716\u793a-\u8815\u52d5\u5e6b\u6d66_\u7ba1\u5916\u5f91\u539a\u8584\u5ea6\u6bd4\u8f03\u5716-En-scaled.jpg\" alt=\"Peristaltic pump tubing diameter\" width=\"75%\" \/><\/p>\n<ul>\n<li><strong>Tubing Hardness:<\/strong> The hardness of the tubing affects the pump&#8217;s load and lifespan. Ensure the tubing can withstand the fluid&#8217;s backpressure.<\/li>\n<li><strong>Sterile and Aseptic Operations:<\/strong> If there is a need for dispensing sterile or high-purity liquids, it is advisable to select peristaltic tubing that can withstand autoclaving. This type of material is suitable for handling sterile solutions, disinfectant solutions, and other liquids, such as culture media and buffer solutions in microbiology, as well as infusions and dialysis applications in the medical field.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<div style=\"background-color: #e9eef0; padding: 10px 20px;\"><strong>Read more:<\/strong>\u00a0<a title=\"Microbiology Test and Sterilization\" href=\"https:\/\/www.rocker.com.tw\/en\/application\/microbiological_test\/\" rel=\"noopener\">Microbiology Test and Sterilization<\/a><\/div>\n<p>&nbsp;<\/p>\n<hr \/>\n<p>&nbsp;<\/p>\n<h2 style=\"text-align: justify;\"><a id=\"P7\"><\/a>Laboratory Peristaltic Pumps Applications<\/h2>\n<p>&nbsp;<\/p>\n<p>Peristaltic pumps can distribute a wide range of fluids, including sterile solutions, abrasive fluids, corrosive fluids, shear-sensitive fluids, and viscous fluids.<\/p>\n<p>&nbsp;<\/p>\n<p><a title=\"Buller Dispensing Peristaltic Pump\" href=\"https:\/\/www.rocker.com.tw\/en\/product\/laboratory-pump-en\/dispensing-peristaltic-pump-p-en\/buller-600-dispensing-peristaltic-pump\/\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"aligncenter\" src=\"https:\/\/www.rocker.com.tw\/wp-content\/uploads\/2024\/06\/Buller-600-1-scaled.jpg\" alt=\"Buller 600 Dispensing Peristaltic Pump\" width=\"50%\" height=\"\" \/><\/a><\/p>\n<p style=\"text-align: center;\">\u25b2\u00a0<a title=\"Buller peristaltic pump\" href=\"https:\/\/www.rocker.com.tw\/en\/product\/food-analysis\/peristaltic_pump-dsp\/buller-600-dsp-dispensing-peristaltic-pump\/\">Buller 600<\/a> features a built-in program specifically designed for microbial distribution, making it especially suitable for water quality microbiology, food microbiology, and pre-processing tasks such as E. coli testing.<\/p>\n<p>&nbsp;<\/p>\n<h3 style=\"text-align: justify;\">Peristaltic Pumps Applications<strong>:<\/strong><\/h3>\n<p>&nbsp;<\/p>\n<ul>\n<li><strong>Microbiology Labs:<\/strong> Distribution of culture media, buffers, diluents, and various sterile solutions.<\/li>\n<li><strong>Medical and Biotech:<\/strong> Infusion, dialysis, extracorporeal circulation, and high-purity liquid analysis.<\/li>\n<li><strong>Pharmaceutical and Food Processing:<\/strong> Precise control of drug, beverage, and food ingredient flow.<\/li>\n<li><strong>Fermentation Food:<\/strong> Adding starter cultures to food ingredients at a consistent rate.<\/li>\n<li><strong>Chemical and Environmental Engineering:<\/strong> Transporting corrosive liquids and wastewater treatment.<\/li>\n<li><strong>Laboratory Reagent Distribution:<\/strong> Precise reagent and buffer distribution.<\/li>\n<li><strong>Industrial Applications:<\/strong> Ink distribution in printing, dye transport in textiles.<\/li>\n<li><strong>Aquarium Industry:<\/strong> Calcium reactor operations.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Reference<br \/>\n<\/strong><\/p>\n<ul>\n<li><a href=\"https:\/\/en.wikipedia.org\/wiki\/Peristaltic_pump\">Peristaltic pump, Wikipedia<\/a><\/li>\n<li><a href=\"https:\/\/www.thomaspumps.com\/en-is\/knowledge-hub\/peristaltic-pump\">About Peristaltic Pump Technology, THOMAS<\/a><\/li>\n<li><a href=\"https:\/\/en.wikipedia.org\/wiki\/Peristaltic_pump\">Peristaltic pump, Wikipedia<\/a><\/li>\n<li><a href=\"https:\/\/www.graylineinc.com\/whitepapers\/peristaltic-pump-tubing.html\">Peristaltic Pump Tubing, GRAYLINE<\/a><\/li>\n<li><a href=\"https:\/\/www.coleparmer.com\/blog\/2019\/06\/18\/pumping-challenging-fluids-with-peristaltic-pumps\/\">Pumping Challenging Fluids with Peristaltic Pumps, antylia blog, Cole-Parmer<\/a><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<hr \/>\n<p>&nbsp;<\/p>\n<h2><strong><span style=\"font-size: 24px;\"><a id=\"P8\"><\/a>Frequently Asked Questions (FAQ)<\/span><\/strong><\/h2>\n<p>&nbsp;<\/p>\n<h3><span style=\"color: #000080; font-size: 16px;\"><strong>Q1: How does a peristaltic pump work and why is it contamination-free?<\/strong><\/span><\/h3>\n<p>&nbsp;<\/p>\n<p><strong>A1: <\/strong>A peristaltic pump works by using rollers to compress a flexible tube. As the rollers move along the tubing, they create a continuous compression and release motion that pushes the fluid forward. Since the\u00a0fluid only makes contact with the interior of the tubing and never the pump mechanism, it greatly prevents cross-contamination and simplifies sterilization.<\/p>\n<p>&nbsp;<\/p>\n<h3><span style=\"color: #000080; font-size: 16px;\"><strong>Q2:<\/strong> <strong>How do I choose the right peristaltic pump for laboratory dispensing tasks?<\/strong><\/span><\/h3>\n<p>&nbsp;<\/p>\n<p><strong>A2:<\/strong> The key factors are flow rate and dispensing accuracy. For applications requiring repeated volume dispensing, such as filling culture media or buffers, it is recommended to use a dispensing peristaltic pump with digital control and a handling dispenser, such as the Buller 600 &#8211; DSP.<\/p>\n<p>This set allows users to set dispensing volumes precisely while enabling one-click dispensing, improving both efficiency and operator ergonomics.<\/p>\n<p>&nbsp;<\/p>\n<h3><span style=\"color: #000080; font-size: 16px;\"><strong>Q3:<\/strong> <strong>What types of fluids are well suited for peristaltic pumps?<\/strong><\/span><\/h3>\n<p>&nbsp;<\/p>\n<p><strong>A3:<\/strong> In addition to common aqueous solutions, peristaltic pumps are ideal for:<\/p>\n<ul>\n<li><strong>Shear-sensitive fluids:<\/strong>\u00a0<br \/>\nSuch as proteins or cell suspensions, as the gentle pumping action helps reduce shear stress and preserve biological activity.<\/li>\n<li><strong>Corrosive chemicals:<\/strong> <br \/>\nBy selecting chemical-resistant tubing material (e.g., Silicone or Viton), you can safely transfer acids and bases.<\/li>\n<li><strong style=\"font-size: 16px;\">High-viscosity liquids:<\/strong><span style=\"font-size: 16px;\">\u00a0<br \/>\nSuch as oils or syrups in food analysis.<\/span><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3><span style=\"color: #000080; font-size: 16px;\"><strong>Q4:<\/strong> <strong>How does a dispensing peristaltic pump automate laboratory workflows?<\/strong><\/span><\/h3>\n<p>&nbsp;<\/p>\n<p><strong>A4:<\/strong> Dispensing peristaltic pumps like the\u00a0<strong>Buller 600 &#8211; DSP<\/strong>\u00a0feature programmable modes. Users can freely set parameters, such as <strong>dispensing volume, flow rate, number of cycles, and interval time<\/strong> to match their workflow. This enables automatic and highly repeatable filling of vials or bottles, reducing manual pipetting errors while improving laboratory efficiency and throughput.<\/p>\n<p>&nbsp;<\/p>\n<h3><span style=\"color: #000080; font-size: 16px;\"><strong>Q5:<\/strong> <strong>What should I consider when choosing tubing for my peristaltic pump?<\/strong><\/span><\/h3>\n<p>&nbsp;<\/p>\n<p><strong>A5:<\/strong> When selecting tubing for a peristaltic pump, consider the following factors:<\/p>\n<ul>\n<li>the <strong>chemical compatibility<\/strong> with the fluid being transferred.<\/li>\n<li>the <strong style=\"font-size: 16px;\">inner diameter (ID)<\/strong><span style=\"font-size: 16px;\"> of the tubing: the diameter determines the achievable flow rate and affects dispensing accuracy.<\/span><\/li>\n<li>Additional requirements, such as mechanical durability, or whether the tubing is autoclavable.<\/li>\n<\/ul>\n<p>Using the appropriate tubing helps ensure stable flow rates, high repeatability, and accurate dispensing performance.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Peristaltic Pump, The Ultimate Tool for Liquid Distribution in Laboratories! &nbsp; Content What is a Peristaltic Pump? Peristaltic Pump Operation Advantages and Features of Peristaltic Pumps Factors Affecting Peristaltic Pump Performance How to Maintain a Peristaltic Pump? How to Select the Appropriate Peristaltic Pump Tubing?? Laboratory Peristaltic Pumps Applications Frequently Asked Questions (FAQ) &nbsp; &nbsp; [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":21122,"parent":0,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"application-category":[],"class_list":["post-21074","application","type-application","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.1.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Peristaltic Pump, The Ultimate Tool for Liquid Distribution in Labs!<\/title>\n<meta name=\"description\" content=\"Peristaltic pump is essential for liquid distribution in labs, accurate and quantitative dosing, flow regulation, and self-priming.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.rocker.com.tw\/en\/application\/peristaltic-pump\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Peristaltic Pump, The Ultimate Tool for Liquid Distribution in Labs!\" \/>\n<meta property=\"og:description\" content=\"Peristaltic pump is essential for liquid distribution in labs, accurate and quantitative dosing, flow regulation, and self-priming.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.rocker.com.tw\/en\/application\/peristaltic-pump\/\" \/>\n<meta property=\"og:site_name\" content=\"Rocker\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-21T07:05:56+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.rocker.com.tw\/wp-content\/uploads\/2024\/07\/\u61c9\u7528icon_\u8815\u52d5\u5e6b\u6d66.png\" \/>\n\t<meta property=\"og:image:width\" content=\"250\" \/>\n\t<meta property=\"og:image:height\" content=\"250\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"7 minutes\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Peristaltic Pump, The Ultimate Tool for Liquid Distribution in Labs!","description":"Peristaltic pump is essential for liquid distribution in labs, accurate and quantitative dosing, flow regulation, and self-priming.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.rocker.com.tw\/en\/application\/peristaltic-pump\/","og_locale":"en_US","og_type":"article","og_title":"Peristaltic Pump, The Ultimate Tool for Liquid Distribution in Labs!","og_description":"Peristaltic pump is essential for liquid distribution in labs, accurate and quantitative dosing, flow regulation, and self-priming.","og_url":"https:\/\/www.rocker.com.tw\/en\/application\/peristaltic-pump\/","og_site_name":"Rocker","article_modified_time":"2026-04-21T07:05:56+00:00","og_image":[{"width":250,"height":250,"url":"https:\/\/www.rocker.com.tw\/wp-content\/uploads\/2024\/07\/\u61c9\u7528icon_\u8815\u52d5\u5e6b\u6d66.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.rocker.com.tw\/en\/application\/peristaltic-pump\/","url":"https:\/\/www.rocker.com.tw\/en\/application\/peristaltic-pump\/","name":"Peristaltic Pump, The Ultimate Tool for Liquid Distribution in Labs!","isPartOf":{"@id":"https:\/\/www.rocker.com.tw\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.rocker.com.tw\/en\/application\/peristaltic-pump\/#primaryimage"},"image":{"@id":"https:\/\/www.rocker.com.tw\/en\/application\/peristaltic-pump\/#primaryimage"},"thumbnailUrl":"https:\/\/www.rocker.com.tw\/wp-content\/uploads\/2024\/07\/\u61c9\u7528icon_\u8815\u52d5\u5e6b\u6d66.png","datePublished":"2024-07-30T03:26:14+00:00","dateModified":"2026-04-21T07:05:56+00:00","description":"Peristaltic pump is essential for liquid distribution in labs, accurate and quantitative dosing, flow regulation, and self-priming.","breadcrumb":{"@id":"https:\/\/www.rocker.com.tw\/en\/application\/peristaltic-pump\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.rocker.com.tw\/en\/application\/peristaltic-pump\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.rocker.com.tw\/en\/application\/peristaltic-pump\/#primaryimage","url":"https:\/\/www.rocker.com.tw\/wp-content\/uploads\/2024\/07\/\u61c9\u7528icon_\u8815\u52d5\u5e6b\u6d66.png","contentUrl":"https:\/\/www.rocker.com.tw\/wp-content\/uploads\/2024\/07\/\u61c9\u7528icon_\u8815\u52d5\u5e6b\u6d66.png","width":250,"height":250,"caption":"\u5206\u914d\u578b\u8815\u52d5\u5e6b\u6d66"},{"@type":"BreadcrumbList","@id":"https:\/\/www.rocker.com.tw\/en\/application\/peristaltic-pump\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.rocker.com.tw\/en\/"},{"@type":"ListItem","position":2,"name":"Applications","item":"https:\/\/www.rocker.com.tw\/en\/application\/"},{"@type":"ListItem","position":3,"name":"Peristaltic Pump"}]},{"@type":"WebSite","@id":"https:\/\/www.rocker.com.tw\/en\/#website","url":"https:\/\/www.rocker.com.tw\/en\/","name":"Rocker","description":"Rocker - make filtration easy!","publisher":{"@id":"https:\/\/www.rocker.com.tw\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.rocker.com.tw\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.rocker.com.tw\/en\/#organization","name":"Rocker","url":"https:\/\/www.rocker.com.tw\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.rocker.com.tw\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.rocker.com.tw\/wp-content\/uploads\/2020\/09\/email-logo-1.png","contentUrl":"https:\/\/www.rocker.com.tw\/wp-content\/uploads\/2020\/09\/email-logo-1.png","width":500,"height":91,"caption":"Rocker"},"image":{"@id":"https:\/\/www.rocker.com.tw\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/rocker-scientific","https:\/\/www.youtube.com\/c\/RockerScientific\/featured"]}]}},"_links":{"self":[{"href":"https:\/\/www.rocker.com.tw\/en\/wp-json\/wp\/v2\/application\/21074","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.rocker.com.tw\/en\/wp-json\/wp\/v2\/application"}],"about":[{"href":"https:\/\/www.rocker.com.tw\/en\/wp-json\/wp\/v2\/types\/application"}],"author":[{"embeddable":true,"href":"https:\/\/www.rocker.com.tw\/en\/wp-json\/wp\/v2\/users\/2"}],"version-history":[{"count":5,"href":"https:\/\/www.rocker.com.tw\/en\/wp-json\/wp\/v2\/application\/21074\/revisions"}],"predecessor-version":[{"id":29126,"href":"https:\/\/www.rocker.com.tw\/en\/wp-json\/wp\/v2\/application\/21074\/revisions\/29126"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.rocker.com.tw\/en\/wp-json\/wp\/v2\/media\/21122"}],"wp:attachment":[{"href":"https:\/\/www.rocker.com.tw\/en\/wp-json\/wp\/v2\/media?parent=21074"}],"wp:term":[{"taxonomy":"application-category","embeddable":true,"href":"https:\/\/www.rocker.com.tw\/en\/wp-json\/wp\/v2\/application-category?post=21074"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}